For the complete documentation index, see llms.txt. This page is also available as Markdown.

GM01 Specification Sheet

GM01 4G Mesh Node

The GXC GM01 Mesh Node enables a G101 or G501 Access Point to wirelessly connect to the GXC Onyx Gateway Node. This is accomplished using self-interference mitigation techniques, allowing access and backhaul carriers to co-exist in CBRS Band 48. Together with GXC's Onyx Platform for orchestration, management, and SAS registration, the GM01 provides coverage extension and rapid deployment in areas where wired infrastructure is unavailable.

Backhaul

Parameter
Specification

Band Support

Band 48 CBRS

Radio Technology

LTE: CAT 12, up to 2 CA, 2x20 MHz

Antenna Configuration

1T2R

Antenna Connector

2 x Type N

TX Power

20 dBm max RMS

RX Sensitivity

-92 dBm per 10 MHz carrier

SIM Support

Dual-SIM, 2FF, external access

Access

Parameter
Specification

Band of Operation

Band 48 CBRS

Antenna Configuration

2T2R

Antenna Connectors: AP Input

2 x Type N

Antenna Connectors: AP Antenna

2 x Type N

Max AP Input Power

33 dBm per port

Antenna Isolation: Access to Backhaul

45 dB minimum

Insertion Loss AP Interface

2.6 dB typical

Hardware Specifications

Parameter
Specification

Power: Nominal Vin

48 VDC

Input Voltage Range

36 V to 60 V

Isolation

Input to Field-GND: 2.5 kVDC

Power Consumption

20 W maximum

AP Data Interface

RJ45 1GbE IEEE-802.3ab, non-PoE

Wireless Diagnostic Interface

Wi-Fi diagnostic AP, 2.4 GHz

Installation

Pole or Wall Mount *

Dimensions

13.9 x 9.7 x 5.3 in

Weight

18.75 lb (8.505 kg)

Environmental Specifications

Parameter
Specification

Operating Temperature

-40°C to +55°C

Storage Temperature

-45°C to +85°C

Humidity

5% to 95% RH

Atmospheric Pressure

751 to 1014 mbar (sea level to 2000 meters altitude)

Water / Dust Ingress

IP66

Operational Vibration (Random)

+12 dB/octave from 5 to 10 Hz, 0.04 m2/s3 from 10 to 50 Hz, -12 dB/octave from 50 to 100 Hz, 3 axes x 30 minutes, per IEC 60068-2-64 (Fh)

Operational Shock

100 half-sine pulses at 50 m/s2 with 11 ms duration each of 6 directions per IEC 60068-2-27 (Ea)

Salt-Fog Corrosion

240 hr at 35°C, 5% NaCl Salt Mist per IEC 60068-2-11 (Ka)

Certifications

FCC part 15 (US) FCC part 96 (US)

Global Part Numbers

Part Number
Description

GXC-MEN-001

GM01 Mesh Node


  • The Mounting Kit must be ordered separately. The GXC GM01 is designed to operate in conjunction with a G101 or G501 Access Point, which is required for the GM01 to function.

  • Specifications and ID are subject to change without notice.

Last updated