# G101 AP Hardware Installation Guide

## About this Guide

This guide provides the information you need to install a GXC G101 Outdoor 4x250mW Access Point. It also includes a general description of the unit, guidelines for using it, and an overview of its capabilities.

{% hint style="info" %}
**NOTE:** Installation of this device should only be performed by a licensed Certified Professional Installer (CPI) per limitations set forth in FCC Part 96 CBRS band, as well as guidelines as summarized by the OnGo Alliance.
{% endhint %}

&#x20;In this guide, the G101 AP may also be referred to as an AP, eNodeB, or eNB.

### General Active RF Installation Instructions

{% hint style="info" %}
**NOTE:** Only experienced installation professionals who are familiar with local building, safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities should install RF devices and antennas. Failure to do so may void the product warranty and may expose the end user to legal and financial liabilities. The manufacturer and its resellers or distributors are not liable for injury, damage or regulation violations associated with the installation of RF Devices or antennas.
{% endhint %}

{% hint style="info" %}
**NOTE:** The G101 AP is designed to be installed and operated outdoors to conform to CBSD—FCC specifications.
{% endhint %}

### Safety Information

For the safety of installation personnel and for the protection of the equipment from damage, please read all safety warnings. If you have any questions concerning the warnings, before installing or powering on the AP contact GXC.

{% hint style="danger" %}
**WARNING:** Read the installation instructions before connecting the system to its power source.
{% endhint %}

{% hint style="danger" %}
**WARNING:** Equipment installation must comply with local and national electrical codes.
{% endhint %}

{% hint style="danger" %}
**WARNING:** This product relies on the existing building or structure for short-circuit (overcurrent) protection. Ensure that the protective device is rated no greater than 20A.
{% endhint %}

{% hint style="danger" %}
**WARNING:** Do not operate this wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified and qualified for such use.
{% endhint %}

{% hint style="danger" %}
**WARNING:** In order to comply with the United States Federal Communications Commission (FCC) radio frequency (RF) exposure limits, antennas should be located at a minimum of 83 centimeters (33 inches) or more from the body of all persons.
{% endhint %}

## Introduction and Features

The GXC G101 is an advanced outdoor 4x250mW two-carrier Access Point (AP) that is compliant with Third-Generation Partnership Program (3GPP) on Long-Term Evolution (LTE) Time Division Duplexing (TDD) technology.

It has four antenna ports and supports either one 4-port or two 2-port RF antenna installations. This AP can operate in Carrier Aggregation (CA) mode or Dual Carrier (DC)/split mode. Each unit comes pre-configured to simplify the installation.

<p align="center"><strong>GXC G101 AP</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FDbxyAKhPShIUbTnTztbD%2Fimage.png?alt=media&amp;token=3072abfb-9113-4c59-a324-fdf1f2ef332b" alt="" width="468"><figcaption></figcaption></figure>

## Onyx Platform Features

The G101 AP is a part of the GXC Onyx Platform that ties together multiple hardware and software elements to bring a full solution to enterprise.

The Onyx Platform provides an enterprise network based on a Cellular Mesh architecture. This private network platform provides high levels of resiliency, flexible deployments, strong coverage in hard-to-reach areas, and a powerful distributed application platform. Mesh nodes are connected via integrated wireless backhaul without the need for fiber.

The Onyx Platform’s features:

* Mesh-based RAN
* Indoor and Outdoor APs
* On-premises core network (available as a hardware appliance, machine image, or edge machine image)
* A robust network management platform tied together with a single pane of glass controller presented as a web-portal

<p align="center"><strong>GXC Onyx Platform Architecture</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FAtjhdtIKPmZXsy5rzPZo%2Fimage.png?alt=media&amp;token=8cf9365e-aea8-4dfa-85b4-284177d7e138" alt="" width="563"><figcaption></figcaption></figure>

## G101 AP Features

As a two-carrier AP, the G101 hardware unit contains two separate APs inside one shell. Having two carriers provides versatile options in how you operate the G101. The available operating modes are described in the next section.

The G101’s primary cell (Pcell) is referred to as Cell 1. The secondary cell (Scell) is referred to as Cell 2. It has four antenna ports and supports either one 4-port or two 2-port Radio Frequency (RF) antenna installations. Each GXC G101 comes pre-configured to simplify the installation.

The two-carrier G101 can operate in one of the following modes:

* Single Carrier (SC) mode — SC describes a scenario where the operator wishes to use only one of the two available cells in the unit. This may be necessary for operators who have limited licensed spectrum or who are planning to use the second carrier later as their network grows. In SC mode, only the primary cell (Pcell), aka Cell 1, is used.
* Dual Carrier (DC)/split mode — DC (split sector) mode enables the operator to run the G101 as two independent carriers for split sector coverage.
* Carrier Aggregation (CA) mode — CA provides the ability to aggregate channels from across the full CBRS range, even channels that are not adjacent. Using CA essentially doubles the downlink capacity when all users have Cat6/7 or later CPE.
* Citizens Broadband Radio System (CBRS) Spectrum Access System (SAS) — CBRS SAS is a multi-vendor Spectrum Access System database where CBRS spectrum use is managed dynamically across operators. The CBRS band covers 3.55–3.70 GHz. Operators must sign up with a SAS provider, which handles the dynamic frequency assignment and release process. GXC provides FCC Part 96 certified APs, including the G101, and Customer Premises Equipment (CPEs) that operate within the Part 96 rules for CBRS.

In addition to the G101 AP’s two carriers and multiple operating modes, the following is a list of other key features. The GXC G101 Low Power Outdoor AP datasheet providing technical specifications is available from GXC.

* Supports standard LTE TDD band 48
* Complies with 3GPP Release 15 standards
* Supports 5/10/15/20 MHz bandwidth per carrier
* Provides excellent Non-Line-of-Sight (NLOS) coverage
* Supports 96 concurrent users per carrier \[x2 carriers (96+96) if operating in DC mode]
* Supports TR-069 network management interface
* Can be accessed via GUI-based local and remote Web management
* Connects to any IP-based backhaul, including public transmission
* Is lightweight and uses low power consumption to reduce OPEX
* Can be used for Internet of Things (IoT) with all mainstream Evolved Packet Core (EPC) vendors
* Ensures secure protection against illegal intrusion
* Supports one 4-port antenna or two 2-port antennas
* Integrated small cell form-factor for quick and easy installation
* Configured out-of-the-box to work with GXC ONYX Platform (Some advanced configuration options may require manual configuration via the AP’s local device management portal.)
* Supports Citizens Broadband Radio Service (CBRS) with dual carrier
* GPS synchronization (built-in)
* Built-in Dynamic Host Configuration Protocol (DHCP) Server, DNS Client, and Network Access Translation (NAT) functionality, providing strong high-speed routing
* Supports Transparent Bridge Mode

## Installation Preparation

The following topics cover the materials and tools needed to install the G101, the operation of the LEDs, the AP’s interfaces, and the recommended location and environment required for the best performance of the AP.

### Installation Preparation - Materials

Check the G101 package to ensure it contains the primary components shown in *Figure: Packing List*. In addition to industry-standard tools, you will need the materials described in *Table: Materials* and the tools shown in *Table: Installation Tools*. Materials may be purchased through a GXC authorized supplier.

<p align="center"><strong>Packing List</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FkGWDohk7JtJGGh1GbspO%2Fimage.png?alt=media&amp;token=8c5dfc2b-bab7-45ed-b572-bc99fe5607f9" alt="" width="563"><figcaption></figcaption></figure>

<p align="center"><strong>Materials</strong></p>

<table><thead><tr><th width="250">Item</th><th>Description</th></tr></thead><tbody><tr><td>Power Cable</td><td>&#x3C; 16 AWG, e.g., 14 AWG, shorter than 330 feet (100 meters)</td></tr><tr><td>Power Plug</td><td>The plug that connects the power cable to the electrical supply</td></tr><tr><td>RF Antenna Cable</td><td>50-ohm feeder, ½” jumper</td></tr><tr><td>RF Antenna</td><td>Omni or directional dual polarized antenna</td></tr><tr><td>Ethernet Cable</td><td>Outdoor CAT6, shorter than 327 feet (100 meters)</td></tr><tr><td>Ground Cable</td><td>If the length of lead is more than 33 feet (10 meters), 6 AWG (10 mm²) grounding cable should be used.</td></tr></tbody></table>

<p align="center"><strong>Installation Tools</strong></p>

| <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2Fmt0sFXZD4Y9B31meFBSe%2Fimage.png?alt=media&amp;token=4a15925d-541a-422f-aa1d-56b8198bae3f" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FISZyEsugcMPrmErqnRJO%2Fimage.png?alt=media&amp;token=e9f96e48-3948-46f0-af8d-4daf08f3249e" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FHmYLooaDDlpOAfh56Lzh%2Fimage.png?alt=media&amp;token=759649f4-1e4c-482d-ad04-e9b87ec79dff" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2F28GAQzELIXvr1WdjLXtc%2Fimage.png?alt=media&amp;token=6782450a-5a50-416d-bec7-ffa9f7625c8e" alt="" data-size="original"> |
| --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Level bar                                                                                                                                                                                                                                                 | Marker pen                                                                                                                                                                                                                                                | Knife                                                                                                                                                                                                                                                     | Pliers                                                                                                                                                                                                                                                    |
| <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FyzqBlcLibGkNz2pbljdz%2Fimage.png?alt=media&amp;token=f1f8ee57-b04a-494a-947d-675d6011aeed" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2F0pROO7n6suG1OggmiI87%2Fimage.png?alt=media&amp;token=714899b3-cd76-42d8-a5cf-7b191fa615d2" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2Fo9rk3j135Z7t5gcgoy9f%2Fimage.png?alt=media&amp;token=26641859-15de-4165-8ede-c0bc9e1f0e64" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FmyzHkPE1axD366jyl8lQ%2Fimage.png?alt=media&amp;token=a4e97670-14f4-4d2e-a4ac-e7e439f4debb" alt="" data-size="original"> |
| Wrench                                                                                                                                                                                                                                                    | Percussion drill and drill heads                                                                                                                                                                                                                          | Hammer                                                                                                                                                                                                                                                    | Phillips-head screwdriver                                                                                                                                                                                                                                 |
| <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FUUf5fXrvSEm9LhHapHkr%2Fimage.png?alt=media&amp;token=aebfcf49-762a-49ea-b16c-3f5b0edd934b" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2F7xH9b4tHttfveJJ9tjI6%2Fimage.png?alt=media&amp;token=ab02e453-b75e-403e-9686-3cd17fe85851" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FpFwTbWxjbdS5t4kL8q2j%2Fimage.png?alt=media&amp;token=dca3c32f-1997-4892-98a2-d9da9724bfe1" alt="" data-size="original"> | <img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FyhjYxKxJYhKqWwfqjuwJ%2Fimage.png?alt=media&amp;token=6bee8bbb-3e7e-414f-a039-a39c745e71a3" alt="" data-size="original"> |
| Cable vice (crimper)                                                                                                                                                                                                                                      | Tape measure                                                                                                                                                                                                                                              | 0.05 cm (5 mm)                                                                                                                                                                                                                                            | Cable vice (crimper)                                                                                                                                                                                                                                      |

### Installation Preparation - Interfaces and LEDs

The following figure and tables describe the G101 AP’s LED status indicators and interfaces.

<p align="center"><strong>LEDs and Interfaces</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FEHow7zgEOyWqy4o9mBTh%2Fimage.png?alt=media&amp;token=5ab2411f-3473-4d5c-84aa-8caf3434e1a6" alt="" width="545"><figcaption></figcaption></figure>

<p align="center"><strong>LEDs</strong></p>

<table><thead><tr><th width="120">LED</th><th width="120">Color</th><th>Status</th><th>Description</th></tr></thead><tbody><tr><td>PWR</td><td>Green</td><td>Steady on</td><td>Power is on</td></tr><tr><td>PWR</td><td>Green</td><td>OFF</td><td>No power supply</td></tr><tr><td>CELL1</td><td>Green</td><td>OFF</td><td>CELL1 is inactive</td></tr><tr><td>CELL1</td><td>Green</td><td>Fast flash: 0.1 s on, 0.1 s off</td><td>CELL1 is deactivated</td></tr><tr><td>CELL1</td><td>Green</td><td>Slow flash: 1 s on, 1 s off</td><td>CELL1 is activated</td></tr><tr><td>CELL2</td><td>Green</td><td>OFF</td><td>CELL2 is inactive</td></tr><tr><td>CELL2</td><td>Green</td><td>Fast flash: 0.1 s on, 0.1 s off</td><td>CELL2 is deactivated</td></tr><tr><td>CELL2</td><td>Green</td><td>Slow flash: 1 s on, 1 s off</td><td>CELL2 is activated</td></tr><tr><td>ALM</td><td>Red</td><td>Steady on</td><td>Hardware alarm</td></tr><tr><td>ALM</td><td>Red</td><td>OFF</td><td>No alarm</td></tr></tbody></table>

<p align="center"><strong>Interfaces</strong></p>

<table><thead><tr><th width="250">Interface</th><th>Description</th></tr></thead><tbody><tr><td>ETH/PoE</td><td>RJ-45 interface (FE/GE)<br>Used for power supply, debug or data backhaul.<br>PoE++, complies with IEEE 802.3bt standard</td></tr><tr><td>GPS</td><td>GPS antenna interface, N type connector</td></tr><tr><td>ANT0</td><td>External antenna interface 1, N type connector</td></tr><tr><td>ANT1</td><td>External antenna interface 2, N type connector</td></tr><tr><td>ANT2</td><td>External antenna interface 3, N type connector</td></tr><tr><td>ANT3</td><td>External antenna interface 4, N type connector</td></tr></tbody></table>

### Installation Preparation - Location and Environment

The G101 can be installed on a pole or a wall. For the best signal coverage, place the AP in an unobstructed location. In addition to network planning, when determining where to place the AP, you need to consider the best location for signal coverage. Avoid locating the unit in areas where there may be extreme temperatures, harmful gases, unstable voltages, volatile vibrations, loud noises, flames, explosives, or electromagnetic interference (e.g., large radar stations, transformer substations). Avoid areas prone to impounded water, soaking, leakage, or condensation. The following table lists the environmental specifications.

<p align="center"><strong>Environmental Specifications</strong></p>

<table><thead><tr><th width="250">Item</th><th>Description</th></tr></thead><tbody><tr><td>Operating Temperature</td><td>-40°F to 131°F / -40°C to 55°C</td></tr><tr><td>Storage Temperature</td><td>-49°F to 158°F / -45°C to 70°C</td></tr><tr><td>Relative Humidity</td><td>5% to 95% RH</td></tr><tr><td>Atmospheric Pressure</td><td>70 kPa to 106 kPa</td></tr><tr><td>Safety Voltage</td><td>42 V to 58 V</td></tr></tbody></table>

### Grounding and Lightning Protection

You must protect the G101 AP, antenna, and GPS against lightning. All GXC APs have a floating ground on the power system. Following are guidelines concerning grounding.

* The yellow-green ground wire must be at least 6 AWG (10 mm2) diameter.
* Always place the grounding as near as possible to the equipment.
* Connect to a reliable outdoor grounding point (earth) using one ground screw.
* The connection of the grounding points and ground bar needs to be tight and reliable. Rustproofing the terminals, e.g., with antioxidant coating or grease, is required.

### Weatherproofing

To protect the connection points from weather and climate, clean each connection point before installing cold shrink tubes, per the following instructions (*Figure: Weatherproofing with Cold Shrink Tubes*).

{% stepper %}
{% step %}
Insert the cable into the cold shrink tube.
{% endstep %}

{% step %}
Tighten the connector.
{% endstep %}

{% step %}
Push the cold shrink tube to the top joint and pull out the strip.
{% endstep %}

{% step %}
Ensure the cold shrink tube is tightly fitted with the connection.

<p align="center"><strong>Weatherproofing with Cold Shrink Tubes</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FXDJDqPWNv9tStF8R8bpx%2Fimage.png?alt=media&amp;token=79b8a4d1-08da-485f-bd67-c104afb6b5fc" alt="" width="546"><figcaption></figcaption></figure>

For GPS antenna weatherproofing, use all-weather electrical tape and mastic tape, per the following figure (*Figure: Weatherproofing GPS Antenna*).

<p align="center"><strong>Weatherproofing GPS Antenna</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2Fkkfue6jACDqvxn5thyqU%2Fimage.png?alt=media&amp;token=08cdbd7d-e11d-469f-a5a8-6761144a9f70" alt="" width="519"><figcaption></figcaption></figure>

{% hint style="info" %}
**NOTE:** Make sure that the wrapping direction of the last layer is from the bottom up. The last layer should be tight enough to keep it from cracking.
{% endhint %}
{% endstep %}
{% endstepper %}

## Installation

The following topics include the G101 installation process overview, instructions for GPS antenna installation, instructions for wall and pole mounting, and instructions for cabling the unit.

### Installation Process Overview

*Table: Installation Overview* provides an overview of the installation process.

<p align="center"><strong>Installation Overview</strong></p>

<table><thead><tr><th width="100">Step</th><th>Description</th></tr></thead><tbody><tr><td>1</td><td>Install GPS antenna on the G101</td></tr><tr><td>2</td><td>Install the G101 on a pole or wall</td></tr><tr><td>3</td><td>Connect RF cable(s) and antenna(s)</td></tr><tr><td>4</td><td>Attach Ethernet and grounding cables</td></tr><tr><td>5</td><td>Power on the G101 to check LED status</td></tr><tr><td>6</td><td>Enter basic configuration, then reboot, and check the unit’s status in GUI and OMC.</td></tr></tbody></table>

### Install GPS Antenna

{% hint style="danger" %}
**WARNING:** Ensure the antennas are connected to the ANT ports before powering up the G101. The wireless signal transmission power can cause bodily injury and damage to the AP and RF power amplifier devices.
{% endhint %}

{% hint style="info" %}
**NOTE:** Read the following GPS antenna installation requirements before installing it on the G101.
{% endhint %}

* Make that the buildings in the vicinity do not block the antenna and the space above the antenna has 45 degrees of clearance.
* The GPS antenna should be installed within 45 degrees to the lightning rod (*Figure: GPS Installation Requirements*).
* Do not install the GPS antenna near other transmitting and receiving equipment, to avoid interference. Do not install it under a microwave antenna or high voltage cable. Avoid the direction of radiation from other transmitting antennas to the GPS antenna.
* When two or more GPS antennas are installed, it is recommended to keep the spacing of more than 6.74 feet (2 meters) between antennas and install multiple GPS antennas in different locations to prevent simultaneous interference.
* GPS antenna feeders cannot be grounded together with ground conductors of interfering equipment such as air conditioners, motors, and pump motors, etc. to prevent external interference from being introduced into the antenna system.

<p align="center"><strong>GPS Installation Requirements</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2F2Uka6esYUACEdH4A82qX%2Fimage.png?alt=media&amp;token=79d39366-c4d1-421a-a88d-24714d890b97" alt="" width="424"><figcaption></figcaption></figure>

The GPS antenna system includes an antenna and a connector. The two parts should be assembled according to *Figure: GPS Antenna Installation*.

<p align="center"><strong>GPS Antenna Installation</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FynHnRmOZYiELXxIwxsse%2Fimage.png?alt=media&amp;token=34338131-7bcb-491c-b15e-c48927090120" alt=""><figcaption></figcaption></figure>

After assembling the GPS antenna, the connector must be waterproofed with shrink tubing or all-weather electrical tape and mastic tape. Refer to the *Weatherproofing* section.

### Install the G101 AP on a Pole

The G101 AP’s mounting bracket is assembled in manufacturing before packing. The only action required by the installer is to attach the assembly to the pole.

<p align="center"><strong>G101 Pole Mounting Bracket</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2F34yjWTaU77X2fzBYECsF%2Fimage.png?alt=media&amp;token=a4f3bb98-1ab1-4e3d-9e43-b06464d5377e" alt="" width="563"><figcaption></figcaption></figure>

Check to make sure that the diameter of the pole is in the range of 1.6–2.8 inches (40–70 mm). The position of the AP on the pole should be at least 47 inches (120 cm) in height.

Follow the steps below to install the unit on a pole.

{% stepper %}
{% step %}
Unscrew the four hex nuts of the assembled pole bracket. Slide the two omega clamps to the left and then turn them up or down (*Figure: Omega Clamps*).

<p align="center"><strong>Omega Clamps</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FpogfDUx5GOXSQnzdn4Z5%2Fimage.png?alt=media&amp;token=98e55202-3543-49e6-9f0f-72f21967fd85" alt="" width="563"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Place the bracket on the pole with the screw holes and arrow facing up, considering the height requirements described above. Turn the two omega clamps to the proper position and slide the clamps onto the bolts as shown in *Figure: Attach Bracket to Pole*.
{% endstep %}

{% step %}
Fasten the four hex nuts with a pair of adjustable wrenches.

<p align="center"><strong>Attach Bracket to Pole</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FYS0ZzUsXqfxW0b71G9vE%2Fimage.png?alt=media&amp;token=2bca66b0-441a-4006-9821-cbfd23975643" alt="" width="547"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Using the two pins and two hooks on the bracket on the back of the AP for alignment, attach the unit to the mounting bracket on the pole. Adjust the position of the AP until its mounting bracket is firmly attached to the pole mounting bracket.

<p align="center"><strong>Pole Bracket Alignment Holes and Slots</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FhEOHLHH0Iw2ded1QkqtI%2Fimage.png?alt=media&amp;token=be67316f-fcba-4858-9be3-6fd04a93b571" alt="" width="563"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Ensure that the hooks and pins of the AP’s bracket are properly inserted into the slots and holes in the pole bracket (*Figure: Attach G101 to Bracket*).

<p align="center"><strong>Attach G101 to Bracket</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2Fmd6Dbx2Td8q1nv9Z8wbe%2Fimage.png?alt=media&amp;token=e75872b9-96a8-438c-948d-c3bff414fac1" alt="" width="291"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Tighten the screw on the top of the bracket using a Phillips-head screwdriver to complete the installation (*Figure: Completed Pole Mounting*)

<p align="center"><strong>Completed Pole Mounting</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FgFYaoU6lbCAxld98PMOK%2Fimage.png?alt=media&amp;token=91987a10-811b-4bfb-94d2-f26931fdd361" alt="" width="469"><figcaption></figcaption></figure>
{% endstep %}
{% endstepper %}

### Install the G101 AP on a Wall

{% hint style="warning" %}
**CAUTION:** It is the responsibility of the installer to ensure that the wall can bear at least four times the weight of the G101.
{% endhint %}

Follow the steps below to install the unit on the wall.

{% stepper %}
{% step %}
Take apart the assembled pole mounting bracket to remove the omega clamps and four bolts. The pole mounting bracket with the omega clamps and bolts removed serves as the wall mounting bracket.
{% endstep %}

{% step %}
Place the installation bracket on the wall with the arrow facing upward, as shown in *Figure: Mark and Drill Holes*. Mark the drilling locations using a pencil or marker.

<p align="center"><strong>Mark and Drill Holes</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FCpxVzmQM8Frxn9xD5ahx%2Fimage.png?alt=media&amp;token=a60641d4-fcba-45d2-92e7-bb69fc524857" alt="" width="469"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Drill two holes in the wall to match the diameter of the expansion bolts.
{% endstep %}

{% step %}
Check the up/down direction of the installation bracket and then attach it to the wall using expansion bolts (*Figure: Attach with Expansion Bolts*).

<p align="center"><strong>Attach with Expansion Bolts</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FYdMUqMSKxwdJEqB4vI1W%2Fimage.png?alt=media&amp;token=27ef3a21-df34-4f7f-aa84-968b44d4b6d2" alt="" width="507"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Using the two pins and two hooks on the bracket on the back of the AP for alignment, attach the AP to the mounting bracket on the wall. Adjust the position of the AP until its mounting bracket is firmly attached to the wall mounting bracket. Ensure that the hooks and pins of the AP’s bracket are properly inserted into the slots and holes in the wall bracket.

<p align="center"><strong>Wall Bracket Alignment Holes and Slots</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FsZzvtiaNzzxE3yYStFjh%2Fimage.png?alt=media&amp;token=75399b63-b2bf-4778-8a9c-7a4d4f0184ae" alt="" width="563"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Tighten the bolt on the top of the bracket using a Phillips-head (cross) screwdriver to complete the installation (*Figure: Attach G101 to Wall Bracket*).

<p align="center"><strong>Attach G101 to Wall Bracket</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2Fygkgx5u2tIyaQNuzE8F3%2Fimage.png?alt=media&amp;token=ce5e9317-59fa-440c-ba4b-e777ea6edf7c" alt="" width="314"><figcaption></figcaption></figure>
{% endstep %}
{% endstepper %}

### Connect Cables

The following topics cover cable layout requirements, GPS cable connections RF cable connections, WAN cable connections, and ground cable connections. Instructions for opening and closing the wiring cavity are also provided.

{% hint style="info" %}
**NOTE:** When connecting the AP to a Mesh Node, refer to the cabling instructions in the *GXC GM01 Mesh Node Hardware Installation and Configuration Guide*.
{% endhint %}

#### Cable Layout Requirements

Cable layout requirements vary based on the type of cable. The following topics provide general requirements for all cable types, and optical cable specific and grounding cable specific requirements.

**General Requirements**

* Bending radius of antenna feeder cable: 7/8 in > 9.84 in (250 mm), 4/5 in > 14.96 in (380 mm)
* Bending radius of jumper cable: 1/4 in > 1.38 in (35 mm),1/2 in (super soft) > 1.97 in (50 mm), 1/2 in (ordinary) > 5 in (127 mm)
* Bending radius of power cable and grounding cable: > triple the diameter of the cable
* Bind the cables according to the type of cable; intertwining and crossing are forbidden.
* An identification label should be attached after the cable is laid.

**Grounding Cable Requirements**

* The grounding cable must connect to the grounding point.
* The grounding cable must be separated from the signal cables to avoid signal interference.

#### Connect RF Cables

{% hint style="danger" %}
**WARNING:** Ensure the antennas are connected to the ANT ports before powering up the G101. The wireless signal transmission power can cause bodily injury and damage to the AP and RF power amplifier devices.
{% endhint %}

{% stepper %}
{% step %}
Open the dust caps of the ANT0, ANT1, ANT2, and ANT3 interfaces that you plan to use.
{% endstep %}

{% step %}
Insert the RF cables into cold shrink tubes.
{% endstep %}

{% step %}
Connect RF cables to the antenna interfaces on the G101 and tighten them with a wrench to 12-15 in-lbs. or 1.4-1.7 NM torque.

{% hint style="info" %}
**NOTE:** Antenna ports ANT0 and ANT1 connect to the primary cell (Pcell), or Cell 1. Antenna ports ANT2 and ANT3 connect to the secondary cell (Scell), or Cell 2.
{% endhint %}
{% endstep %}

{% step %}
Push the cold shrink tube to the top joint and pull out the strip.
{% endstep %}

{% step %}
Connect the other end of the RF cables to the external antennas, which also need weatherproof protection.
{% endstep %}
{% endstepper %}

#### Install the POE++ Ethernet Cable

The Ethernet cable connector is located inside the wiring cavity of the G101. The following topics provide instructions for opening and closing the wiring cavity and connecting the Ethernet cable.

**Open the Wiring Cavity**

{% stepper %}
{% step %}
Unscrew the three captive Phillips head screws on the cover of the AP’s wiring cavity using a Phillips-head screwdriver as shown in *Figure: Wiring Cavity Screws* and lift the cover to access the wiring cavity.

<p align="center"><strong>Wiring Cavity Screws</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FsS3bzMZuzG26fr1DcuIM%2Fimage.png?alt=media&amp;token=ecbe4347-10df-49b6-809d-027fc4365230" alt="" width="189"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Remove the rubber plug from the right cable gland to prepare for insertion of the POE++ Ethernet cable as shown in *Figure: Cable Glands with Plugs*. Do not detach the plugs from the glands in case they are needed in the future.

<p align="center"><strong>Cable Glands with Plugs</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FfuXz8MqTEpXyuZS84GLv%2Fimage.png?alt=media&amp;token=f85ddc51-63b6-4099-93e2-0b75a48e0239" alt="" width="176"><figcaption></figcaption></figure>
{% endstep %}
{% endstepper %}

**Connect Ethernet Cable**

{% stepper %}
{% step %}
Route the Ethernet cable through the right-side ETH wire groove and flexible rubber gland into the wiring cavity.
{% endstep %}

{% step %}
Connect the Ethernet cable to the ETH interface in the wiring cavity.

<p align="center"><strong>POE++ Ethernet Cable Connection</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FJGvwcGxdopITM1gBbp8d%2Fimage.png?alt=media&amp;token=9fbe288d-701b-4ec9-8184-5a87f0a449a7" alt="" width="257"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Connect the Ethernet cable to the POE ++ interface of the POE adapter.
{% endstep %}

{% step %}
Connect the LAN interface of the POE adaptor to a LAN switch or a router for maintenance and backhaul.
{% endstep %}
{% endstepper %}

**Wiring Cavity Waterproofing**

After the installation is complete, you must close the wiring cavity of the equipment and ensure that it is waterproof.

{% stepper %}
{% step %}
Close the wiring cavity making sure that all unused openings have plugs in place.
{% endstep %}

{% step %}
Tighten the three Phillips head screws to seal the wiring cavity.

{% hint style="info" %}
**NOTE:** The POE++ adaptor must be placed in the distribution box for waterproofing.
{% endhint %}
{% endstep %}
{% endstepper %}

#### G101 AP Grounding

The following topics provide grounding requirements for a G101 and instructions for connecting the ground to the unit.

**Pole Grounding**

The purpose of pole grounding is to protect the equipment as much as possible from potential damage of lightning overvoltage. However, the interfaces between the G101 and the outside world mainly include the power system, grounding system, antenna feeder and lightning receiving device, and signal line. Therefore, any damage caused by lightning primarily comes from the voltage difference between the equipment in the AP and one or more of the four interfaces. The pole grounding is shown in *Figure: Pole Grounding*.

<p align="center"><strong>Pole Grounding</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FKgMEekqZutPmRwxqJvNk%2Fimage.png?alt=media&amp;token=7ed022e0-d7da-40ec-a6f8-c804137ac214" alt="" width="479"><figcaption></figcaption></figure>

{% stepper %}
{% step %}
The installation position of the grounding bar should meet the design requirements. The mounting pole and tower body must be connected to the lightning protection network or grounded with a separate lead.
{% endstep %}

{% step %}
The diameter of the grounding wire should meet the design requirements. The copper nose must be used for grounding, and the grounding resistance is required to be less than 10 ohms. If the resistance of the public network communication equipment placed in other systems is less than 10 ohms, the grounding network of the system should be overlapped.
{% endstep %}

{% step %}
The grounding wire must be the whole wire material. When laying, it should be bound separately with other cables. All grounding wires should be fixed with wire core or binding tape with a fixed spacing of 0.3 m.
{% endstep %}

{% step %}
The copper bar must be used for the grounding bar, and the specification of the grounding bar shall meet the design requirements. If there are no specific requirements in the design, 300 × 40 × 4 mm and fixed with expansion bolts.
{% endstep %}

{% step %}
The grounding wire must be made of the whole cable material, the intermediate joint is strictly prohibited, and the excess length should be cut. The skin shall be complete, and the insulation resistance of the core wire to the ground (or metal isolation layer) shall meet the technical requirements of the cable.
{% endstep %}

{% step %}
The grounding wire shall be connected to the integrated grounding bar of the building. If it is impossible to connect to the integrated grounding bar of the building, the appropriate grounding point can be selected according to the integrated grounding situation of the indoor building. The selection of grounding point must be higher than the grounding grid, and the feeder grounding shall be towards the downward direction of the feeder, never upward.
{% endstep %}

{% step %}
The grounding electrode of the self-built grounding grid for the outdoor antenna of the tunnel must meet the design requirements. The buried depth of the grounding electrode and the welding quality of the flat iron meet the specification requirements. In principle, the buried depth of the grounding electrode shall not be less than 0.7 m. The non-self-built grounding network shall be connected to the grounding network of the owner.
{% endstep %}

{% step %}
The G101 grounding, power adapter grounding, distribution box grounding and feeder grounding must be connected to the grounding bar independently, and the grounding bar must have a path from the lead to the earth.
{% endstep %}
{% endstepper %}

**Connect Grounding Cable**

Prepare the grounding cable according to the actual measurements and requirements of the specific installation site. The G101 AP has two grounding screws located on the bottom of the unit, as shown in *Figure: Grounding Screws*. Follow the steps below the figure to connect the ground cable.

{% hint style="info" %}
**NOTE:** All GXC APs have a floating ground on the power system.
{% endhint %}

<p align="center"><strong>Grounding Screws</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FVRPOgP4WTeZW9IsLEJOE%2Fimage.png?alt=media&amp;token=559edbc8-2f68-4421-9167-48dc05938632" alt="" width="437"><figcaption></figcaption></figure>

{% stepper %}
{% step %}
Unscrew one grounding screw, connect one end of the ground cable to the grounding screw, and retighten the screw.
{% endstep %}

{% step %}
Repeat the previous step for the second grounding screw.
{% endstep %}

{% step %}
Once the AP is installed at the outdoor location, the other end of the ground cable needs to connect to a good earth grounding point (*Figure: Connecting Cables and Grounding Screws*).

<p align="center"><strong>Connecting Cables and Grounding Screws</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FoM37oFByJmnbNrrJ2El3%2Fimage.png?alt=media&amp;token=fbb92319-a92d-4c4d-90f4-0be63f2de8dc" alt="" width="521"><figcaption></figcaption></figure>
{% endstep %}
{% endstepper %}

Before the G101 is installed at its final destination, perform the steps in the [Power on to Check LED Status](#power-on-to-check-led-status) and [Configure Basic Parameters](#configure-basic-parameters) sections. Upon successful testing, the AP will be ready for installation at the cell site. Seal and weatherproof all the connection points, and rustproof where needed.

### Completed Installation

<p align="center"><strong>Completed Weatherproof Installation</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FLfhbuZJYljoFncv3xTEj%2Fimage.png?alt=media&amp;token=474c68d6-9be4-4d7b-8e76-5c91fc694f8f" alt="" width="282"><figcaption></figcaption></figure>

### Power on to Check LED Status

{% hint style="danger" %}
**WARNING:** Ensure the antennas are connected to the ANT ports before powering up the G101. The wireless signal transmission power can cause bodily injury and damage to the G101 and RF power amplifier devices.
{% endhint %}

Power on the G101, and check that the LED indicators are lighting as expected: Power is steady green, cell activated is slow flash green, and there are no alarms (*Figure: Check LEDs*), per *Table: LEDs*.

<p align="center"><strong>Check LEDs</strong></p>

<figure><img src="https://4084968256-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgSxa0NIdBp5aDw7Lf2N9%2Fuploads%2FiX7osgudq4LwgNDmRUof%2Fimage.png?alt=media&amp;token=3b3077d1-d5f1-4c4f-b31d-88ad63854a19" alt="" width="152"><figcaption></figcaption></figure>

### Configure Basic Parameters

When first installing and testing the AP, GXC recommends configuring the primary cell (Pcell)/Cell 1 carrier settings (without enabling CA, DC, or SAS) for simple verification that the new AP is operational. Once it is confirmed to be operational, you can then refer to the appropriate configuration guide(s) for the operating mode you plan to use.

## Add and Manage G101 AP in the Onyx Portal

For detailed information on adding and managing G101 APs in the Onyx Portal interface, refer to *4G Onyx Portal Operations Guide > Manage Access Points*.

## Appendix: Regulatory Compliance

FCC and ISEDC Compliance information is provided in the following topics.

### FCC Compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

{% hint style="warning" %}
**WARNING:** This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 33 inches (83 cm) between the radiator and your body.
{% endhint %}

### ISEDC Compliance <a href="#toc100931604" id="toc100931604"></a>

This device complies with Innovation, Science, and Economic Development Canada license-exempt RSS standard(s).

Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 33 inches (83 cm) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.gxc.io/hw/lte/4g-access-points/g101/g101-ap-hardware-installation-guide.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.