For the complete documentation index, see llms.txt. This page is also available as Markdown.

GM03 Specification Sheet

GM03 Mesh Node

The GXC GM03 Mesh Node enables an Access Point to wirelessly connect to the GXC Onyx Gateway Node. This is accomplished using self-interference mitigation techniques, allowing access and backhaul carriers to co-exist in CBRS Band n48. Together with GXC's Onyx Platform for orchestration, management, and SAS registration, the GM03 provides coverage extension and rapid deployment in areas where wired infrastructure is unavailable.

Backhaul

Parameter
Specification

Band Support

Band n48 CBRS

Radio Technology

5G,40 MHz

Antenna Configuration

2T2R

Antenna Connector

2 x Type N connectors

TX Power

2x20 dBm conducted,

RX Sensitivity

-96 dBm per 10 MHz carrier

Insertion Loss (Filter)

2.6 dB (typical)

SIM Support

Dual-SIM, 2FF, external access

Hardware Specifications

Parameter
Specification

Band of Operation

Band n48 CBRS

Antenna Configuration

2T2R

Antenna Connectors

AP Input: 2 x Type N connectors AP Antenna: 2 x Type N connectors

Max TX from Mesh AP

33 dBm per port

Antenna Isolation

Backhaul Access: 45 dB (minimum)

Insertion Loss (AP Interface)

2.6 dB (typical)

Parameter
Specification

Power: Nominal Vin

48 VDC

Input Voltage Range

36 V to 60 V

Isolation

Input to Field-GND: 2.5 kVDC

Power Consumption

20 W (maximum)

AP Data Interface

RJ45 1 GbE IEEE-802.3ab, non-PoE

Wireless Diagnostic Interface

Wi-Fi diagnostic AP, 2.4 GHz

Installation

Pole or Wall Mount *

Dimensions

13.9 x 9.7 x 5.3 in

Weight

18.75 lb (8.505 kg)

Environmental Specifications

Parameter
Specification

Operating Temperature

-40°C to +55°C

Storage Temperature

-45°C to +85°C

Humidity

5% to 95% RH

Atmospheric Pressure

751 to 1014 mbar (sea level to 2000 meters altitude)

Water / Dust Ingress

IP66

Operational Vibration (Random)

+12 dB/octave from 5 to 10 Hz, 0.04 m2/s3 from 10 to 50 Hz, -12 dB/octave from 50 to 100 Hz, 3 axes x 30 minutes, per IEC 60068-2-64 (Fh)

Operational Shock

100 half-sine pulses at 50m/s2 with 11 ms duration each of 6 directions, per IEC 60068-2-27 (Ea)

Salt-Fog Corrosion

240 hours at 35°C, 5% NaCl salt mist per IEC 60068-2-11 (Ka)

Certifications

FCC Part 96

Global Part Numbers

Part Number
Description

GXC-MEN-003

GM03 Mesh Node

  • The GXC GM03 is designed to operate in conjunction with an Access Point, which is required for the GM03 to function. Contact GXC on specific AP Model.

  • Specifications and ID are subject to change without notice.

Last updated