For the complete documentation index, see llms.txt. This page is also available as Markdown.

Applying Power

The following sections detail the installation of the field replaceable power supply units (PSU) and the connection to the AC Line to power the Onyx FHM.

The PSUs are pre-installed in the Onyx FHM. The PSU is a hot swappable field replaceable unit (FRU) and can be replaced while the equipment is operating if the remaining (second) PSU is installed and in operation.

The following instructions detail how to install a new PSU field FRU in the Onyx FHM.

PSU Replacement

PSU FRU Removal

1

Locate the release tab on the PSU FRU and press and hold the blue release tab to the right to unlock the PSU from the power bay.

2

While holding down the release tab, grip the PSU's handle and firmly pull it out of the power bay.

PSU FRU Removal

PSU FRU Installation

1

Align the new PSU with the empty power bay, ensuring the PSU’s power connector is in the correct orientation (see Figure 24).

2

Carefully slide the new PSU into the power bay and gently push until the front surface of the PSU is flush with the front surface of the case.

3

An audible click will be heard when the PSU is installed correctly. The PSU will not go in all the way if it is inserted in the wrong orientation.

PSU FRU Installation

Connection of AC Power

1

Ensure there is enough power available on the selected electrical circuit to supply the Onyx FHM. The maximum system power consumption is 188.22 watts with an input voltage of 100-240V AC. It is recommended to ensure that enough power is available from the power distribution system prior to installation.

2

The Onyx-FRU is designed to support 1 + 1 power redundancy. Ensure that both PSU FRUs have been properly installed before powering up the equipment.

3

Insert the AC PSU Cable Receptacle of 1 pc. of the included power cords into the AC PSU ensuring that it is fully inserted.

4

Insert the standard AC Plug into the desired AC outlet. If necessary, switch on power strip that PSU(s) are plugged into.

5

Verify that the power supply is operating. The LED on the PSU will illuminate Green designating normal operation.

Installing the AC Power Cord into the PSU FRU

Verifying System Operation

Front Panel LED

Verify successful boot up of Onyx FHM by checking the system LED Tree located on the front panel. When operating normally, the PWR, FAN, and SYS LEDs should all display green.

Onyx FHM Front Panel LED Tree — GNSS

Onyx FHM Front Panel LED — GNSS

LED Condition
Equipment Status

Off

GNSS is not configured. NOTE: Need NOS to activate this feature.

Solid Green

GNSS is in normal state. Self-survey is complete. NOTE: Need NOS to activate this feature.

Blinking Green

GNSS is in learning state. Self-survey is not completed. NOTE: Need NOS to activate this feature.

Solid Yellow

Power up. GNSS is not tracking any satellite. NOTE: Need NOS to activate this feature.

Blinking Yellow

GNSS Antenna is shorted to ground. NOTE: Need NOS to activate this feature.

Onyx FHM Front Panel LED — SYNC

LED Condition
Equipment Status

Off

System timing synchronization is disabled, or unit is in free-run mode. NOTE: need NOS to activate this feature.

Solid Green

System timing core (1588 and SyncE) is synchronized to external timing source (ex: GNSS, 1PPS, PTP, BITS, etc.) NOTE: need NOS to activate this feature

Blinking Green

System is synchronized in SyncE mode.

NOTE: need NOS to activate this feature.

Solid Yellow

System timing core is in acquiring state or holdover mode.

Blinking Yellow

System timing synchronization failed.

NOTE: need NOS to activate this feature.

Onyx FHM Front Panel LED — SYS

LED Condition
Equipment Status

Off

Reserved

Solid Green

System boot complete

Blinking Green

Reserved

Solid Yellow

Reserved

Blinking Yellow

System boot not complete

Onyx FHM Front Panel LED — FAN

LED Condition
Equipment Status

Off

Reserved

Solid Green

All FAN Modules Operating Normally

Blinking Green

Reserved

Solid Yellow

Reserved

Blinking Yellow

One or more FAN module(s) have failed or no FAN module present

Onyx FHM Front Panel LED — PWR

LED Condition
Equipment Status

Off

No power or in shutdown mode.

Solid Green

System power good & BMC is present & BMC power good

Solid Yellow

System power good & BMC is absent

Onyx FHM Front Panel LED — ID

LED Condition
Equipment Status

Off

No Power

Blinking Blue

Beacon feature is enabled

Onyx FHM Front Panel LED — PSU FRU LED

LED Condition
Equipment Status

Off

No AC power input to this PSU.

Flashing Red

No DC power output from this PSU.

Flashing Green

DC present, only standby output on. Poor contact.

Green

PSU DC output ON and OK.

Red

PSU failure.

Alternating Flashing Green and Red

Warning. Working conditions are not satisfied. Please check the voltage, electric current, and temperature.

Onyx FHM Management Port LED — Left LED

LED Condition
Equipment Status

Off

1G no link

Solid Green

1G link-up

Blinking Green

1G TX/RX activity

Onyx FHM Management Port LED — Right LED

LED Condition
Equipment Status

Off

No activity

Solid Amber

10M/100M link-up

Blinking Amber

10M/100M TX/RX activity

Post Installation Steps

1

After installing the FHM, connect the RUs to it, starting with port 0.

Ensure all RUs are of the same model.

2

Onboard the FHM.

Refer to 5G Onyx Portal Operations Guide > Add FHM.

Last updated