Troubleshooting Information
This section describes basic Onyx Edge troubleshooting information.
View Onyx Edge Details
To view an Onyx Edge’s details:
Open the Onyx Edge's Details page (Onyx Portal, click Equipment > Onyx Edge tab > Onyx Edge details page > Overview tab).
The Overview tab displays the selected Onyx Edge's details, including its configuration, status, and connected equipment. For detailed information, see 4G Onyx Portal Operations Guide > View Onyx Edge Details.
To view Onyx Edge's events and alerts, click the Events & Alerts tab.
The Events & Alerts tab displays alerts and events generated by the Onyx Edge.
The Alerts panel lists device alerts with the Date, Status, Alert Name, and Severity, and includes a filter to view specific alert types.
The Events panel displays system events for the selected date/time and duration. The table includes the Timestamp, Module, Event Type, Entity, and Event Description, with filtering options for several fields.
For detailed information, see 4G Onyx Portal Operations Guide > View Onyx Edge Details.
To view Onyx Edge's logs, click the Logs tab.
The Logs tab displays Onyx Edge logs for the selected date/time and duration, and log details including timestamp, service, tag, type, and log text are displayed.
To download the logs in .csv format, click Download. In the Download Logs dialog box, select the timestamps and the limit, which specifies the maximum number of logs to be included in the .csv file, then click Save. The downloaded .csv file contains log details including timestamp, service, tag, type, and log text.
For detailed information, see 4G Onyx Portal Operations Guide > View Onyx Edge Details.
View Connected APs, Mesh Nodes, and Subscribers
To view the list of active APs, Mesh nodes, and subscribers connected to an Onyx Edge:
For the list of active APs, view the Onyx Edge’s details page > Overview tab > Connected Access Point section.
For the list of Mesh Nodes, view the Onyx Edge’s details page > Overview tab > Mesh Node section.
For the list of active subscribers, view the Onyx Edge’s details page > Overview tab > Subscribers section.
For detailed information, see 4G Onyx Portal Operations Guide > View Onyx Edge Details.
Run Commands on the Onyx Edge
This section describes how to:
Run Commands on Onyx Edge from Onyx Portal
To run generic commands on an Onyx Edge from the Onyx Portal:
In the Onyx Edge’s details page (Onyx Portal > Equipment > Onyx Edge tab > Onyx Edge details page), in the upper-right corner of the page, click Actions.
Upgrade – (GXC Administrators, Super Administrators, and Administrators only.) Upgrade the Onyx Edge’s software version, move the Onyx Edge to the required target upgrade group. For more information, see the 4G Onyx Portal Operations Guide > Move an Onyx Edge from one Upgrade Group to Another section.
Reboot Onyx Edge – (GXC Administrators, Super Administrators, and Administrators only.) Reboot the Onyx Edge. Services will be down while the equipment reboots.
A confirmation dialog box is displayed. To confirm, click Yes.
Restart Services on Onyx Edge – (GXC Administrators, Super Administrators, and Administrators only.) Restart the Onyx Edge’s core services. All active UE will be detached. Connectivity will be down until the services resume.
A confirmation dialog box is displayed. To confirm, click Yes.
Ping – (GXC Administrators, Super Administrators, and Administrators only.) Ping the Onyx Edge’s host.
Enter the following details, then click Ping.
Host – (Required) The host’s IP address.
Packets (default 4) – (Optional) The number of packets to send. Default: 4.
Reboot AP – (GXC Administrators, Super Administrators, and Administrators only.) Reboot all or a specific AP.
Enter the following details, then click Execute.
Reboot AP – Select to reboot a specific AP in the network.
In the Select an AP dropdown, select the AP’s serial number.
Reboot All APs – Select to reboot all APs in the network.
Reboot Neighbor Updated AP – (GXC Administrators, Super Administrators, and Administrators only.) Schedule reboots for APs with pending neighbor changes:
Reboot all APs with reboot pending at a chosen time, including immediately.
Reboot a specific AP by serial number, if it has a reboot pending, at a chosen time including immediately.
Detach Subscriber – (GXC Administrators, Super Administrators, and Administrators only.) Forcibly detach an active subscriber/UE.
Enter the following details, then click Execute.
Subscriber IMSI – The subscriber’s IMSI.
Force Config Sync – (GXC Administrators, Super Administrators, and Administrators only.) Trigger a full configuration synchronization.
Force Subscriber Config Sync – (GXC Administrators, Super Administrators, and Administrators only.) Trigger a configuration synchronization for a specific subscriber.
Trigger Debug Information Collection – (GXC Administrators, Super Administrators, and Administrators only.) Collect logs and telemetry from Onyx Edge.
List Debug Information Files in OE – (GXC Administrators, Super Administrators, and Administrators only.) View downloadable debug files available on the Onyx Edge.
Generic Command – (GXC Administrators only.) Run generic commands on the Onyx Edge.
The Run Onyx Edge Command dialog box is displayed.
Enter the following details, then click Execute:
Command – (Required) The command to run.
Parameters – (Optional) Parameters for the command.
Run Commands on Onyx Edge as agw_user
As agw_user, you can SSH into and run the following commands on your Onyx Edge.
To SSH into an Onyx Edge as agw_user, run the following command:
For more information, see agw_user.
Command Descriptions
Related Documentation
4G Onyx Portal Operations Guide
GXC Glossary
Contact GXC
To get in touch with GXC, please visit https://gxc.io/contact-us/.
Last updated
Was this helpful?